DN-300 Series Hardware Setup
Hardware-specific setup procedures for DN-300 series devices including mounting configurations, power options, and mode switching.
For complete system installation including network switch setup and server configuration, see the System Installation Guide.
DN-300 Environmental Requirements
Site Requirements
- Environmental: Operating temperature 0°C to +40°C (32°F to 104°F), humidity 10-90% non-condensing
- Ventilation: Minimum 12mm (0.5 inch) clearance on at least one side with airflow through rack if rack mounted
- Power: 12VDC external adapter or PoE+ (IEEE 802.3at) switch
- Network: CAT-6A or CAT-7 cable for 10GbE copper connection, or fiber cable with SFP+ modules for fiber connections
Mounting Options
Desktop Mounting
- Place device on stable, level surface
- Ensure rear panel access for connections
- Allow minimum 12mm (0.5 inch) clearance on at least one side for ventilation
Wall Mounting
- Use included mounting brackets and template
- Secure brackets to wall with appropriate fasteners
- Attach device to brackets with included screws
- Verify secure mounting before connecting cables
Rack Mounting
Horizontal Rack Mount Kit (DN-300-RMK)
- Capacity: Up to 4 devices per 1U rack space
- Configurations: 1-up or 2-up mounting options as shown in technical drawing
- Ventilation: Minimum 1/4U open rack space above and below stacked units required
- Installation: Follow included instructions for proper device spacing and airflow
Vertical Rack Mount Kit (DN-300-RMKV)
- Capacity: Up to 10 devices per 6U rack space
- Access: Individual device access for configuration and service
- Installation: Follow kit instructions for proper vertical mounting
Power Configuration
External Power
- Power: 12VDC ± 5%, 2.5A maximum (30W max, 13.5W typical)
- Connector: 5.5mm/2.1mm screw-locking connector
- Connect included 12VDC power adapter to device power connector
- Rotate connector collar to secure screw-locking connection
- Verify POWER LED illuminates green
PoE+ Power
- Standard: IEEE 802.3at (minimum 30W per port)
- Cable: CAT-6A S/FTP or CAT-7 required
- Maximum Distance: 100 meters (328 feet)
- Connect CAT-6A or CAT-7 cable from device 10GbE port to PoE+ switch port
- Verify switch supports IEEE 802.3at with adequate power budget
- Confirm POWER LED illuminates green
Power Redundancy
- Both external and PoE+ power can be connected simultaneously
- Device operates normally if either power source fails
Operating Mode Configuration
DN-300 devices support different operating modes that can be configured either using the front panel button or remotely through DisplayNet Manager® or API commands.
Front Panel Mode Configuration
- Locate MODE SWITCH button on front panel (small recessed button)
- DN-300H Mode Switching Procedure:
- Press and hold the MODE SWITCH button until the TX or RX LED starts flashing
- The flashing LED indicates the unit is switching modes
- Release the button and wait for the LED to stop flashing
- The mode switch is complete when the LED stops flashing and remains solid
- DN-300T Mode Switching Procedure:
- Press and hold the MODE SWITCH button until the TX, RX, or both LEDs start flashing
- Release the MODE SWITCH button once flashing begins
- Press and release the MODE SWITCH button to scroll through mode selections
- Mode selection order: TRX (both LEDs) → TX (single LED) → RX (single LED) → repeat
- Once desired mode is selected, press and hold the MODE SWITCH button until the LEDs stop flashing
- Release the button - the unit will reset and become operational in the new mode
- Mode lights indicate current selection:
- TX LED (green): TX mode active
- RX LED (green): RX mode active
- Both LEDs (green): TRX mode active (DN-300T only)
- Allow 2-3 seconds for mode change to complete
- Mode setting is automatically retained through power cycles
Default Power-Up Modes
- DN-300H: Powers up in TX mode by default
- DN-300T: Powers up in TRX mode by default
- Settings are retained from last configuration if changed
Remote Mode Configuration
Operating modes can also be controlled remotely through:
DisplayNet Manager®:
- Access device settings for the target DN-300 device
- Select desired operating mode from the device configuration panel
- Monitor MODE LED for confirmation
API Commands:
- Connect to DisplayNet Server® API on port 6980
- Send mode change commands using DisplayNet API protocol
- Integrate with third-party control systems as required
Network Connection Setup
10GbE Copper Connection
- Cable: CAT-6A S/FTP or CAT-7 shielded cables
- Maximum Length: 100 meters (328 feet)
- Connect CAT-6A or CAT-7 cable to device 10GbE RJ45 port
- Connect to 10GbE switch port
- Verify 10GbE LINK LED shows green
10GbE Fiber Connection (SFP+)
- Modules: MSA-compliant SFP+ transceivers only
- Fiber Types: Single-mode (up to 30km) or multi-mode (up to 300m)
- Insert SFP+ module into device cage until it clicks
- Connect fiber cables to SFP+ module LC connectors
- Verify 10GbE LINK LED shows green
1GbE LAN Connection
- Function: Automatically bridged to active 10GbE interface
- Cable: CAT-5e minimum, maximum 100 meters
- Connect peripheral devices to 1GbE port as needed
- Verify 1GbE LAN LED shows activity
PoE+ Switch Requirements (if using PoE+ power)
- IEEE 802.3at Support: Minimum 30W per port capability